The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Portrait of Daniel Förnvik. Photo

Daniel Förnvik

Associate professor

Portrait of Daniel Förnvik. Photo

Visibility of single spiculations in digital breast tomosynthesis

Author

  • Pontus Timberg
  • Magnus Dustler
  • Daniel Förnvik
  • Sophia Zackrisson

Summary, in English

Purpose: To investigate the visibility of single spiculations in digital breast tomosynthesis (DBT). Method: Simulated spheres (6 mm diameter) with single spiculations were added to projection images acquired on a DBT system (MAMMOMAT Inspiration, Siemens). The spiculations had a cylindrical shape and were randomly, diagonally aligned (at four different positions: +/- pi/4 or +/- 3 pi/4) at a plane parallel to the detector. They were assumed to consist of a fibroglandular tissue composition. The length of the spiculations was 5 mm while the diameter varied (0.12 - 0.28 mm). Reconstructed central slices of the lesion, separated by insertion in fatty or dense breasts (100 images in each), were used in 4-alternative forced choice (4AFC) human observer experiments. Three different reconstructions were used: filtered back projection (FBP) with 1 mm thick slices and a statistical artifact reduction reconstruction (SAR) method generating 1 and 2 mm thick slices. Five readers participated and their task was to locate the spiculation in randomly presented images from the whole image set (4 diameters x 100 images). The percent correct (PC) decision was determined in both fat and dense tissue for all spiculation diameters and reconstructions. Results: At a PC level of 95% the required diameter was about 0.17 - 0.22 mm in dense tissue, and 0.18 - 0.26 mm in fatty tissue (depending upon reconstruction). Conclusions: SAR was found to be a promising alternative to FBP. The visibility of single spiculations was determined. The required diameter depends on both tissue composition and reconstruction.

Department/s

  • Medical Radiation Physics, Malmö
  • Department of Translational Medicine

Publishing year

2013

Language

English

Pages

86731-86731

Publication/Series

Medical Imaging 2013: Image Perception, Observer Performance, And Technology Assessment

Volume

8673

Document type

Conference paper

Publisher

SPIE

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Keywords

  • Breast Tomosynthesis
  • Lesion simulation
  • Spiculation
  • 4AFC
  • Reconstruction methods

Conference name

SPIE Medical Imaging, 2013

Conference date

2013-02-09 - 2013-02-14

Conference place

Lake Buena Vista (Orlando area), Florida, United States

Status

Published

Research group

  • Medical Radiation Physics, Malmö

ISBN/ISSN/Other

  • ISSN: 1996-756X
  • ISSN: 0277-786X