Evaluation of image quality of lumbar spine images: a comparison between FFE and VGA.

Author

  • Anders Tingberg
  • Magnus Båth
  • Markus Håkansson
  • Joakim Medin
  • Jack Besjakov
  • Michael Sandborg
  • Gudrun Alm-Carlsson
  • Sören Mattsson
  • Lars Gunnar Månsson

Summary, in English

Purpose: The aim of the present study is to compare two different methods for evaluation of the quality of clinical X-ray images. Methods: Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. Results: In the VGA study, images with low noise were preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study, the visibility of the lesions was independent of the sharpness and the noise level. No correlation was found between the two image quality measures. Conclusions: FFE is a precise method for evaluation of image quality, but the results are only valid for the type of lesion used in the study, whereas VGA is a more general method for clinical image quality assessment. The results of the FFE study indicate that there might be a potential to lower the dose levels in lumbar spine radiography without losing important diagnostic information.

Department/s

  • Medical Radiation Physics, Malmö
  • Radiology Diagnostics, Malmö

Publishing year

2005

Language

English

Pages

53-61

Publication/Series

Radiation Protection Dosimetry

Volume

114

Issue

1-3

Document type

Journal article

Publisher

Oxford University Press

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Status

Published

Research group

  • Medical Radiation Physics, Malmö
  • Radiology Diagnostics, Malmö

ISBN/ISSN/Other

  • ISSN: 1742-3406