The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Portrait of Anders Tingberg. Photo

Anders Tingberg

Associate professor

Portrait of Anders Tingberg. Photo

Does software optimization influence the radiologists' perception in low dose paediatric pelvic examinations?

Author

  • H. Precht
  • D. Waaler
  • C. B. Outzen
  • J. B. Brock Thorsen
  • T. Steen
  • M. B. Hellfritzsch
  • H. Aagesen
  • A. K. Holst
  • P. Le
  • S. Lindequist
  • L. Rasmussen
  • A. Tingberg

Summary, in English

Purpose: To investigate whether software optimisation can improve an observers’ perception of image quality in low dose paediatric pelvic examinations. Methods: Twenty-five consecutive patients (3–7 years old) were referred for a pelvic digital radiography (DR) examination. They were prospectively enrolled in the study over a 3-month period. Images were taken at 80 kV and 2–4 mAs depending on pelvic thickness (9–15 cm). A small focal spot, 130 cm SID: 10 cm air gap and 1 mm Al and 0.2 mm Cu additional filtration were also utilised. Images were acquired on a Canon DR detector and optimised using five different combinations of the multi-frequency processing software (Canon DR system version NE, Version 7.1 with SPECTRA) to comply with the ALARA principle. Image quality was blindly evaluated using the subjective Visual Grading Analysis (VGA) by five experienced musculoskeletal radiologists, including the evaluation of six anatomical image quality criteria (scored from 1 to 5). Results: Consistently, the VGA results indicated that by using software optimised parameters, image quality was suitable for diagnosis in 48–71% of all images. Based on a VGC analysis all software optimised images did have significant better image quality then the one with just the clinical settings. Noise reduction was the software setting which influenced the image quality the most, area under the curve (AUC) of 0.8172 95%CI 0.7953–0.8375. Conclusion: Software optimisation improve the radiologists' perception of image quality and should thus be thoroughly considered within clinical practise. Noise reduction is the software parameter which has the greatest influence.

Department/s

  • Medical Radiation Physics, Malmö

Publishing year

2019-01-01

Language

English

Pages

143-147

Publication/Series

Radiography

Volume

25

Issue

2

Document type

Journal article

Publisher

W.B. Saunders

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Keywords

  • Image quality
  • Paediatric femur
  • Software optimisation
  • Visual Grading Analysis

Status

Published

Research group

  • Medical Radiation Physics, Malmö

ISBN/ISSN/Other

  • ISSN: 1078-8174