The browser you are using is not supported by this website. All versions of Internet Explorer are no longer supported, either by us or Microsoft (read more here: https://www.microsoft.com/en-us/microsoft-365/windows/end-of-ie-support).

Please use a modern browser to fully experience our website, such as the newest versions of Edge, Chrome, Firefox or Safari etc.

Portrait of Anders Tingberg. Photo

Anders Tingberg

Associate professor

Portrait of Anders Tingberg. Photo

Evaluation of the possibility to use thick slabs of reconstructed outer breast tomosynthesis slice images

Author

  • Hannie Petersson
  • Magnus Dustler
  • Anders Tingberg
  • Pontus Timberg

Summary, in English

The large image volumes in breast tomosynthesis (BT) have led to large amounts of data and a heavy workload for breast radiologists. The number of slice images can be decreased by combining adjacent image planes (slabbing) but the decrease in depth resolution can considerably affect the detection of lesions. The aim of this work was to assess if thicker slabbing of the outer slice images (where lesions seldom are present) could be a viable alternative in order to reduce the number of slice images in BT image volumes. The suggested slabbing (an image volume with thick outer slabs and thin slices between) were evaluated in two steps. Firstly, a survey of the depth of 65 cancer lesions within the breast was performed to estimate how many lesions would be affected by outer slabs of different thicknesses. Secondly, a selection of 24 lesions was reconstructed with 2, 6 and 10 mm slab thickness to evaluate how the appearance of lesions located in the thicker slabs would be affected. The results show that few malignant breast lesions are located at a depth less than 10 mm from the surface (especially for breast thicknesses of 50 mm and above). Reconstruction of BT volumes with 6 mm slab thickness yields an image quality that is sufficient for lesion detection for a majority of the investigated cases. Together, this indicates that thicker slabbing of the outer slice images is a promising option in order to reduce the number of slice images in BT image volumes.

Department/s

  • Medical Radiation Physics, Malmö

Publishing year

2016

Language

English

Publication/Series

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

Volume

9787

Document type

Conference paper

Publisher

SPIE

Topic

  • Clinical Medicine

Keywords

  • AIP slab
  • Breast tomosynthesis
  • Image quality
  • Lesion depth
  • Slice thickness

Conference name

Medical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment

Conference date

2016-03-02 - 2016-03-03

Conference place

San Diego, United States

Status

Published

Research group

  • Medical Radiation Physics, Malmö

ISBN/ISSN/Other

  • ISBN: 9781510600225