The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria

Author

  • A Almen
  • Anders Tingberg
  • Sören Mattsson
  • Jack Besjakov
  • S Kheddache
  • B Lanhede
  • L G Månsson
  • M Zankl

Summary, in English

In this study we have investigated the image quality of lumbar spine radiographs taken after recording technical and physical parameters. Two technical parameters were altered, tube voltage (70 kV and 90 kV for the anteroposterior (AP) projection and 77 kV and 95 kV for the lateral projection) and sensitivity of the film-screen system (sensitivity class 400 and 600). In total, 85 images were included in the study. Entrance surface dose (ESD) was measured using thermoluminescent dosemeters. The mean value of ESD for the different technique groups varied between 1.9 mGy (90 kV, sensitivity class 400) and 4.6 mGy (70 kV, sensitivity class 400) for the AP projection, and between 6.4 mGy (95 kV, sensitivity class 600) and 20.4 mGy (70 kV, sensitivity class 400) for the lateral projection. Image criteria given in the "European Guidelines on Quality Criteria for Radiographic Images" were used to assess image quality. Two evaluation methods have been employed. A straightforward scoring of fulfilled image criteria, and visual grading analysis using the structures defined in the image criteria. The latter method provided a sharper distinction between groups of images taken using different radiographic techniques. The average number of fulfilled image criteria for the AP projections varied between 0.74 (90 kV, sensitivity class 400) and 0.87 (70 kV, sensitivity class 400). For the lateral projection this number varied between 0.79 (95 kV, sensitivity class 600) and 0.84 (77 kV, sensitivity class 600). This study shows that image criteria are useful tools in clinical studies of image quality.

Publishing year

2000

Language

English

Pages

1192-1199

Publication/Series

British Journal of Radiology

Volume

73

Issue

875

Document type

Journal article

Publisher

British Institute of Radiology

Topic

  • Radiology, Nuclear Medicine and Medical Imaging

Status

Published

ISBN/ISSN/Other

  • ISSN: 1748-880X